From a neighbor’s phone, immediately call the gas ating this or any other appliance. supplier. Follow the gas supplier’s instructions. • Always contact the Dacor Customer Service Team • If you cannot contact the gas supplier, call the fire about problems and conditions that you don’t under- department.
Do not use this appliance in combination with a sur- the cooktop. Do not allow clothing to come into con- face (countertop) ventilation system. Dacor strongly tact with the cooktop and surrounding areas during recommends the installation of a range hood in con- and immediately after use.
Installation Specifications Electrical Requirements Gas Supply Requirements • Be certain that the cooktop being installed is correct for WARNING the gas service being provided (natural gas or LP gas). Also, if operating the cooktop at an altitude above 4000 To prevent an electric shock hazard, the power supply ft.
Installation Specifications WARNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. Product Dimensions All tolerances ±1/16” (±1.6 mm) unless otherwise noted. 4" (10.2 cm) 30" chassis height (76.2 cm) 27 1/2" * 19 1/2"...
Installation Specifications 4" (10.2 cm) chassis height 21" (53.3 cm) 36" (91.4 cm) Axis2 Axis2 33 5/8" * 19 1/2" * (85.4 cm) (49.5 cm) 2 1/8" (5.4 cm) * including embosses bottom of base in side of chassis to cooking surface Model RGC365 Front of cooktop Gas inlet...
This appliance is to be used in conjunction with a suit- • The gas supply piping, gas shut-off valve and the elec- able vent hood or approved Dacor downdraft vent. trical outlet must be located so they do not interfere with the cooktop when it is installed. If installing another All tolerances +1/16”...
Installation Instructions Verify Package Contents Connecting the Gas Line • Hold down brackets (2) WARNING • Grates (2 for RGC304, 3 for RGC365) • Verify that the gas supply meets specifications before • Burner sets (4 for RGC304, 5 for RGC365) connection.
Installation Instructions Installing the Burner Components 1. Remove the burner heads, burner rings, burner caps and grates from their shipping packages. 2. Install the burners as shown. When installing the burn- WARNING er components, twist each piece back and forth until it drops completely into place.
3. Turn on power to the electrical outlet at the circuit when you call. See inside cover for location. breaker or fuse box. Dacor is not responsible for the cost of correcting problems 4. Depress and turn one burner control knob at a time caused by a faulty installation.
Installation Instructions Installation Checklist Parts List Replacement parts may be obtained by contacting Dacor WARNING Customer Service. To ensure a safe and proper installation, the following Dacor Customer Service checklist should be completed by the installer to ensure Phone: (800) 793-0093 (U.S.A. and Canada) that no part of the installation has been overlooked.
Wiring Diagrams 120V, 60Hz. WIRING DIAGRAM RGC365 POWER SUPPLY CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION VERIFY PROPER OPERATION WHEN SERVICING CONTROLS. WIRING ERRORS CAN AFTER SERVICING CAUSE IMPROPER AND DANGEROUS OPERATION. ISOLATOR BOARD P/N 103720 IGNITOR, NO SWITCH LR BURNER RE-IGNITOR IGNITOR, NO SWITCH...
Page 16
Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.com...